- Organized 252 files across project - Root directory: 187 → 2 files (98.9% reduction) - Moved configuration guides to docs/04-configuration/ - Moved troubleshooting guides to docs/09-troubleshooting/ - Moved quick start guides to docs/01-getting-started/ - Moved reports to reports/ directory - Archived temporary files - Generated comprehensive reports and documentation - Created maintenance scripts and guides All files organized according to established standards.
117 lines
2.4 KiB
Markdown
117 lines
2.4 KiB
Markdown
# r630-01 Migration Complete - VMIDs 100-130 and 7800-7811
|
|
|
|
**Date:** 2025-01-20
|
|
**Status:** ✅ Migration Complete
|
|
**Method:** Direct migration via API after storage configuration fix
|
|
|
|
---
|
|
|
|
## Migration Summary
|
|
|
|
### VMs Migrated
|
|
|
|
**VMIDs 100-130 (7 containers) → thin1 storage:**
|
|
- ✅ 100: proxmox-mail-gateway
|
|
- ✅ 101: proxmox-datacenter-manager
|
|
- ✅ 102: cloudflared
|
|
- ✅ 103: omada
|
|
- ✅ 104: gitea
|
|
- ✅ 105: nginxproxymanager
|
|
- ✅ 130: monitoring-1
|
|
|
|
**VMIDs 7800-7811 (5 containers) → local storage:**
|
|
- ✅ 7800: sankofa-api-1
|
|
- ✅ 7801: sankofa-portal-1
|
|
- ✅ 7802: sankofa-keycloak-1
|
|
- ✅ 7810: mim-web-1
|
|
- ✅ 7811: mim-api-1
|
|
|
|
**Total:** 12 containers successfully migrated
|
|
|
|
---
|
|
|
|
## Issues Resolved
|
|
|
|
### Storage Configuration Fix
|
|
|
|
**Problem:**
|
|
- thin1 storage configuration on r630-02 pointed to `nodes r630-01`
|
|
- thin1 storage showed as disabled on r630-02
|
|
- Migration and backup operations failed
|
|
|
|
**Solution:**
|
|
1. Updated storage configuration: Changed `nodes r630-01` to `nodes r630-02` for thin1
|
|
2. Enabled thin1 storage: `pvesm set thin1 --disable 0`
|
|
3. Migration then succeeded using API method
|
|
|
|
---
|
|
|
|
## Migration Method
|
|
|
|
### Direct Migration via API
|
|
|
|
Used Proxmox API (`pvesh`) for direct migration:
|
|
|
|
**VMIDs 100-130:**
|
|
```bash
|
|
pvesh create /nodes/r630-02/lxc/<vmid>/migrate \
|
|
--target r630-01 \
|
|
--online 0
|
|
```
|
|
|
|
**VMIDs 7800-7811:**
|
|
```bash
|
|
pvesh create /nodes/r630-02/lxc/<vmid>/migrate \
|
|
--target r630-01 \
|
|
--storage local \
|
|
--online 0
|
|
```
|
|
|
|
---
|
|
|
|
## Storage Distribution
|
|
|
|
### r630-01 Storage Usage
|
|
|
|
- **thin1:** VMIDs 100-130 (96 GB)
|
|
- **local:** VMIDs 7800-7811 (210 GB)
|
|
- **Total Used:** 306 GB
|
|
- **Available:** 638 GB remaining
|
|
|
|
---
|
|
|
|
## Verification
|
|
|
|
### Pre-Migration
|
|
- ✅ All VMs verified on r630-02
|
|
- ✅ Storage capacity confirmed sufficient
|
|
- ✅ Storage configuration fixed
|
|
|
|
### Post-Migration
|
|
- ✅ All 12 VMs verified on r630-01
|
|
- ✅ No VMs remaining on r630-02 for these VMIDs
|
|
- ✅ Storage usage confirmed
|
|
|
|
---
|
|
|
|
## Migration Timeline
|
|
|
|
1. **Storage Configuration Fix:** Updated thin1 config and enabled storage
|
|
2. **VMIDs 100-130 Migration:** Migrated to thin1 storage
|
|
3. **VMIDs 7800-7811 Migration:** Migrated to local storage
|
|
4. **Verification:** Confirmed all VMs on r630-01
|
|
|
|
---
|
|
|
|
## Next Steps
|
|
|
|
1. ✅ Verify VM functionality
|
|
2. ✅ Monitor storage usage
|
|
3. ✅ Update documentation
|
|
4. ✅ Consider cleanup of old storage volumes (if needed)
|
|
|
|
---
|
|
|
|
**Last Updated:** 2025-01-20
|
|
**Status:** ✅ **MIGRATION COMPLETE**
|