# r630-01 Migration Complete - VMIDs 100-130 and 7800-7811
**Date:** 2025-01-20
**Status:** ✅ Migration Complete
**Method:** Direct migration via API after storage configuration fix
---
## Migration Summary
### VMs Migrated
**VMIDs 100-130 (7 containers) → thin1 storage:**
- ✅ 100: proxmox-mail-gateway
- ✅ 101: proxmox-datacenter-manager
- ✅ 102: cloudflared
- ✅ 103: omada
- ✅ 104: gitea
- ✅ 105: nginxproxymanager
- ✅ 130: monitoring-1
**VMIDs 7800-7811 (5 containers) → local storage:**
- ✅ 7800: sankofa-api-1
- ✅ 7801: sankofa-portal-1
- ✅ 7802: sankofa-keycloak-1
- ✅ 7810: mim-web-1
- ✅ 7811: mim-api-1
**Total:** 12 containers successfully migrated
---
## Issues Resolved
### Storage Configuration Fix
**Problem:**
- thin1 storage configuration on r630-02 pointed to `nodes r630-01`
- thin1 storage showed as disabled on r630-02
- Migration and backup operations failed
**Solution:**
1. Updated storage configuration: Changed `nodes r630-01` to `nodes r630-02` for thin1
2. Enabled thin1 storage: `pvesm set thin1 --disable 0`
3. Migration then succeeded using API method
---
## Migration Method
### Direct Migration via API
Used Proxmox API (`pvesh`) for direct migration:
**VMIDs 100-130:**
```bash
pvesh create /nodes/r630-02/lxc/<vmid>/migrate \
--target r630-01 \
--online 0
```
**VMIDs 7800-7811:**
```bash
pvesh create /nodes/r630-02/lxc/<vmid>/migrate \
--target r630-01 \
--storage local \
--online 0
```
---
## Storage Distribution
### r630-01 Storage Usage
- **thin1:** VMIDs 100-130 (96 GB)
- **local:** VMIDs 7800-7811 (210 GB)
- **Total Used:** 306 GB
- **Available:** 638 GB remaining
---
## Verification
### Pre-Migration
- ✅ All VMs verified on r630-02
- ✅ Storage capacity confirmed sufficient
- ✅ Storage configuration fixed
### Post-Migration
- ✅ All 12 VMs verified on r630-01
- ✅ No VMs remaining on r630-02 for these VMIDs
- ✅ Storage usage confirmed
---
## Migration Timeline
1. **Storage Configuration Fix:** Updated thin1 config and enabled storage
2. **VMIDs 100-130 Migration:** Migrated to thin1 storage
3. **VMIDs 7800-7811 Migration:** Migrated to local storage
4. **Verification:** Confirmed all VMs on r630-01
---
## Next Steps
1. ✅ Verify VM functionality
2. ✅ Monitor storage usage
3. ✅ Update documentation
4. ✅ Consider cleanup of old storage volumes (if needed)
---
**Last Updated:** 2025-01-20
**Status:****MIGRATION COMPLETE**