# Physical Drives and Current Configurations — Proxmox Hosts
2026-03-02 11:37:34 -08:00
2026-04-12 06:12:20 -07:00
> Modern note: This hardware/storage inventory is still useful, but host workload examples can lag behind live CT placement. Use the storage descriptions here together with current VM placement from `docs/04-configuration/ALL_VMIDS_ENDPOINTS.md` before making migration or capacity decisions.
**Last updated:** 2026-04-03
2026-03-02 11:37:34 -08:00
---
## ml110 (192.168.11.10)
| Device | Size | Model | Serial | Configuration |
|--------|--------|------------------------|----------|----------------|
| **sda ** | 931.5G | ST1000DM003-1ER162 (HDD) | Z4YE0TMR | Partitioned: sda1 (1M), sda2 (1G vfat /boot/efi), sda3 (930.5G LVM2). VG **pve ** : swap 8G, root 96G ext4 `/` , **data ** thin pool 794G (CTs 1003, 1004, 1503– 1508, 2102, 2301, 2304– 2308, 2400, 2402, 2403). |
| **sdb ** | 931.5G | ST1000DM003-1ER162 (HDD) | Z4YDLPZ3 | **In VG pve ** — extended `data` thin pool (data_tdata). Pool now ~1.7 TB total. |
**RAID:** None.
**Summary:** 2× 1TB HDDs. Both in use: sda (OS + original data pool); sdb added to pve and used to extend the data thin pool (~930G added). Data/local-lvm pool now ~1.7 TB.
---
## r630-01 (192.168.11.11)
| Device | Size | Model | Serial | Configuration |
|--------|--------|-------------------|--------------|----------------|
| **sda ** | 558.9G | HUC109060CSS600 (SSD) | KSKUZEZF | Partitioned: sda1 (1M), sda2 (1G vfat), sda3 (557G **zfs_member ** ). ZFS used for Proxmox root (rpool). |
| **sdb ** | 558.9G | HUC109060CSS600 (SSD) | KSKM1B4F | Same layout as sda — ZFS mirror partner for root. |
| **sdc ** | 232.9G | CT250MX500SSD1 (SSD) | 2203E5FE090E | Member of **md0 ** (RAID10). |
| **sdd ** | 232.9G | CT250MX500SSD1 | 2203E5FE08F8 | Member of **md0 ** (RAID10). |
| **sde ** | 232.9G | CT250MX500SSD1 | 2203E5FE08FA | Member of **md0 ** (RAID10). |
| **sdf ** | 232.9G | CT250MX500SSD1 | 2203E5FE08F1 | Member of **md0 ** (RAID10). |
| **sdg ** | 232.9G | CT250MX500SSD1 | 2203E5FE095E | Member of **md0 ** (RAID10). |
| **sdh ** | 232.9G | CT250MX500SSD1 | 2203E5FE0901 | Member of **md0 ** (RAID10). |
**RAID:** **md0 ** = RAID10, 6× 233G SSDs → * * ~698G** usable. State: **active ** , 6/6 devices [UUUUUU].
2026-04-12 06:12:20 -07:00
**LVM on md0:** VG **pve ** (single PV `/dev/md0` ). Thin pools: **pve-thin1 ** 208G, **pve-data ** 280G. This host has carried validators, core RPC `2101` , and the edge/private RPC lanes across multiple generations. Verify the current CT set with `pct list` or `ALL_VMIDS_ENDPOINTS.md` instead of relying on the historical `2500– 2505` example.
2026-03-02 11:37:34 -08:00
**Summary:** 2× 559G SSDs (ZFS root) + 6× 233G SSDs (RAID10 → LVM data/thin1). All drives in use.
---
## r630-02 (192.168.11.12)
| Device | Size | Model | Serial | Configuration |
|--------|--------|-------------------|--------------|----------------|
| **sda ** | 232.9G | CT250MX500SSD1 | 2202E5FB4CB9 | Partitioned: sda1 (1M), sda2 (1G vfat), sda3 (231G **zfs_member ** ). ZFS for Proxmox root. |
| **sdb ** | 232.9G | CT250MX500SSD1 | 2203E5FE090D | Same — ZFS mirror for root. |
| **sdc ** | 232.9G | CT250MX500SSD1 | 2203E5FE07E1 | sdc3 → LVM VG **thin2 ** (thin pool → VMIDs 5000, 6000, 6001, 6002). |
| **sdd ** | 232.9G | CT250MX500SSD1 | 2202E5FB186E | sdd3 → LVM VG **thin3 ** (VMIDs 5800, 10237, 8641, 5801). |
| **sde ** | 232.9G | CT250MX500SSD1 | 2203E5FE0905 | sde3 → LVM VG **thin4 ** (VMIDs 7810, 7811). |
| **sdf ** | 232.9G | CT250MX500SSD1 | 2203E5FE0964 | sdf3 → LVM VG **thin5 ** (empty pool after 5000 migrated to thin2). |
| **sdg ** | 232.9G | CT250MX500SSD1 | 2203E5FE0928 | sdg3 → LVM VG **thin6 ** (VMIDs 5700, 6400, 6401, 6402). |
| **sdh ** | 232.9G | CT250MX500SSD1 | 2203E5FE0903 | sdh3 → LVM VG **thin1 ** (thin1-r630-02: 2201, 2303, 2401, 5200– 5202, 6200, 10234). |
**RAID:** None (each data disk is a separate LVM PV).
**Summary:** 2× 233G SSDs (ZFS root) + 6× 233G SSDs (each its own VG: thin1– thin6). All 8 drives in use.
---
2026-04-12 06:12:20 -07:00
## r630-03 (192.168.11.13)
| Device | Size | Model / notes | Configuration |
|--------|--------|---------------|---------------|
| **sda ** | 558.9G | AL14SEB060NY | sda3 → VG **pve ** (swap, root ext4, **data ** thin pool). |
| **sdb ** | 558.9G | HUC109060CSS600 | PV in VG **pve ** ; extends **data ** thin pool (~1 TiB total with sda). |
| **sdc– sdh ** | 232.9G each | Samsung 850/860 EVO 250G | Whole-disk PV → VG **thin1 ** – **thin6** + thin pools; Proxmox * * `thin1-r630-03` ** … * * `thin6-r630-03` ** (~226 GiB each). |
**RAID:** None on data SSDs.
**Summary:** 2× ~559G in **pve ** for OS + thin **data ** /**local-lvm**; six SSDs as **per-disk LVM thin ** (same idea as r630-02). Idempotent provision: `scripts/proxmox/provision-r630-03-six-ssd-thinpools.sh` .
---
## r630-04 (192.168.11.14)
| Device | Size | Model / notes | Configuration |
|--------|--------|---------------|---------------|
| **sda ** | 279.4G | ST9300653SS | sda3 → VG **pve ** (swap, root, **data ** thin pool leg). |
| **sdb ** | 279.4G | HUC106030CSS600 | PV in VG **pve ** ; **data ** thin ~467 GiB. |
| **sdc– sdf ** | 232.9G each | Crucial MX500 | Ceph bluestore OSDs (one VG per disk). |
**RAID:** None.
**Summary:** **pve ** for Proxmox + guest thin storage; four SSDs for Ceph.
---
2026-03-02 11:37:34 -08:00
## Quick reference
| Host | Physical drives | Layout | Unused / notes |
|---------|------------------|--------|-----------------|
| ml110 | 2× 1TB HDD | sda: OS+LVM data; sdb: LVM PV only | **sdb ** — 931G not in any VG |
| r630-01 | 2× 559G + 6× 233G SSD | ZFS root + RAID10 md0 → LVM | All in use |
| r630-02 | 2× 233G + 6× 233G SSD | ZFS root + 6× single-disk LVM (thin1– thin6) | All in use |
2026-04-12 06:12:20 -07:00
| r630-03 | 2× 559G + 6× 233G SSD | **pve ** thin **data ** ~1 TiB + **thin1-r630-03 ** …**thin6-r630-03** on sdc– sdh | All data SSDs in use |
| r630-04 | 2× 279G + 4× 233G SSD | LVM **pve ** + Ceph OSDs on 233G disks | Ceph + **pve ** in use |
2026-03-02 11:37:34 -08:00
To re-check:
`ssh root@<host> 'lsblk -o NAME,SIZE,TYPE,FSTYPE,MODEL,SERIAL; echo; pvs; vgs'`