Files
Sankofa/docs/infrastructure/r630-01-disk-layout.md
defiQUG 33d50fb91e
Some checks failed
API CI / API Lint (push) Successful in 47s
API CI / API Type Check (push) Failing after 47s
API CI / API Test (push) Successful in 1m0s
API CI / API Build (push) Failing after 50s
API CI / Build Docker Image (push) Has been skipped
Build Crossplane Provider / build (push) Failing after 5m51s
CD Pipeline / Deploy to Staging (push) Failing after 29s
CI Pipeline / Lint and Type Check (push) Failing after 36s
CI Pipeline / Build (push) Has been skipped
CI Pipeline / Test Backend (push) Failing after 1m33s
CI Pipeline / Test Frontend (push) Failing after 30s
CI Pipeline / Security Scan (push) Failing after 1m16s
Crossplane Provider CI / Go Test (push) Failing after 3m23s
Crossplane Provider CI / Go Lint (push) Failing after 7m27s
Crossplane Provider CI / Go Build (push) Failing after 3m27s
Deploy to Staging / Deploy to Staging (push) Failing after 30s
Portal CI / Portal Lint (push) Failing after 21s
Portal CI / Portal Type Check (push) Failing after 21s
Portal CI / Portal Test (push) Failing after 21s
Portal CI / Portal Build (push) Failing after 22s
Test Suite / frontend-tests (push) Failing after 30s
Test Suite / api-tests (push) Failing after 49s
Test Suite / blockchain-tests (push) Failing after 30s
Type Check / type-check (map[directory:. name:root]) (push) Failing after 23s
Type Check / type-check (map[directory:api name:api]) (push) Failing after 21s
Type Check / type-check (map[directory:portal name:portal]) (push) Failing after 19s
Validate Configuration Files / validate (push) Failing after 1m52s
CD Pipeline / Deploy to Production (push) Has been skipped
chore: consolidate local WIP (repo cleanup 20260707)
Co-authored-by: Cursor <cursoragent@cursor.com>
2026-07-07 09:41:34 -07:00

3.6 KiB

R630-01 Disk Layout Reference

Overview

This document describes the disk layout for the R630-01 Proxmox VE host based on lsblk output.

Disk Inventory

System Disk: /dev/sda (279.4G)

  • Type: System/OS disk with LVM
  • Partitions:
    • sda1: 1007K (BIOS boot partition)
    • sda2: 1G (EFI boot partition, mounted at /boot/efi)
    • sda3: 278G (LVM physical volume)
  • LVM Volumes:
    • pve-swap: 8G (swap)
    • pve-root: 79.5G (root filesystem, mounted at /)
    • pve-data: 171G (Proxmox data storage)
  • Status: Active system disk
  • Usage: Proxmox VE host OS and base storage

Secondary Disk: /dev/sdb (279.4G)

  • Type: Standalone LVM physical volume (not in volume group)
  • Partitions: None (has LVM2_member signature)
  • Status: Available for use (needs LVM signature removal for Ceph)
  • Model: HUC106030CSS600
  • Recommendations:
    • Ceph OSD (wipe LVM signature first)
    • Proxmox storage pool
    • Backup storage

Ceph Candidate Disks: /dev/sdc through /dev/sdh (6x 232.9G)

  • Type: SSDs - Ready for Ceph OSDs
  • Model: CT250MX500SSD1 (Crucial MX500)
  • Size: ~232.9G each
  • Total Capacity: ~1.4TB
  • Status: All 6 disks available (no partitions, unmounted)
  • Typical Usage: Ceph OSD nodes for distributed storage

Disk Layout Summary

sda (279.4G) - System Disk
├─ sda1 (1007K) - BIOS boot
├─ sda2 (1G) - EFI boot [/boot/efi]
└─ sda3 (278G) - LVM PV
   ├─ pve-swap (8G)
   ├─ pve-root (79.5G) [/]
   └─ pve-data (171G)

sdb (279.4G) - Available

sdc-sdh (6x 232.9G) - Storage/Ceph candidates

Storage Recommendations

Quick Setup (Automated):

# Run on r630-01 directly
./scripts/setup-ceph-osds-r630.sh

# Or run remotely
./scripts/run-ceph-osd-setup-remote.sh L@kers2010

# To include sdb disk as well
./scripts/run-ceph-osd-setup-remote.sh L@kers2010 --include-sdb

Manual Setup:

  1. Verify disk status: Run analyze-r630-disk-layout.sh
  2. Wipe disks (if needed): wipefs -a /dev/sdX
  3. Create OSDs: ceph-volume lvm create --data /dev/sdX
  4. Verify: ceph osd tree

What the automated script does:

  • Checks prerequisites (Ceph installed, cluster accessible)
  • Verifies all 6 SSDs (sdc-sdh) are available
  • Optionally prepares sdb (removes LVM signature)
  • Creates OSDs on all available disks
  • Enables and starts OSD services
  • Verifies Ceph health and OSD status

For Proxmox Storage

  1. Format disks: Use format-ssds-and-check-proxmox.sh
  2. Add to Proxmox: Datacenter > Storage > Add
  3. Choose type: Directory, LVM, or ZFS

For Mixed Use

  • Use sdb for Proxmox storage
  • Use sdc-sdh for Ceph OSDs
  • Keep sda as system disk

Analysis & Verification

  • scripts/analyze-r630-disk-layout.sh - Comprehensive disk analysis
  • scripts/check-proxmox-storage.sh - Quick Proxmox storage check
  • scripts/verify-r630-disks.sh - Disk verification for Ceph

Ceph OSD Setup

  • scripts/setup-ceph-osds-r630.sh - Main setup script (run on r630-01)
  • scripts/run-ceph-osd-setup-remote.sh - Remote execution helper
  • scripts/create-ceph-osds-all-drives.sh - Alternative OSD creation script
  • scripts/create-all-osds-efficient.sh - Efficient OSD creation

Proxmox Storage

  • scripts/format-ssds-and-check-proxmox.sh - Format disks for Proxmox

Notes

  • All disk sizes are approximate (decimal vs binary)
  • Check actual status with lsblk or analysis script
  • Always verify before making changes to disk layout