Some checks failed
API CI / API Lint (push) Successful in 47s
API CI / API Type Check (push) Failing after 47s
API CI / API Test (push) Successful in 1m0s
API CI / API Build (push) Failing after 50s
API CI / Build Docker Image (push) Has been skipped
Build Crossplane Provider / build (push) Failing after 5m51s
CD Pipeline / Deploy to Staging (push) Failing after 29s
CI Pipeline / Lint and Type Check (push) Failing after 36s
CI Pipeline / Build (push) Has been skipped
CI Pipeline / Test Backend (push) Failing after 1m33s
CI Pipeline / Test Frontend (push) Failing after 30s
CI Pipeline / Security Scan (push) Failing after 1m16s
Crossplane Provider CI / Go Test (push) Failing after 3m23s
Crossplane Provider CI / Go Lint (push) Failing after 7m27s
Crossplane Provider CI / Go Build (push) Failing after 3m27s
Deploy to Staging / Deploy to Staging (push) Failing after 30s
Portal CI / Portal Lint (push) Failing after 21s
Portal CI / Portal Type Check (push) Failing after 21s
Portal CI / Portal Test (push) Failing after 21s
Portal CI / Portal Build (push) Failing after 22s
Test Suite / frontend-tests (push) Failing after 30s
Test Suite / api-tests (push) Failing after 49s
Test Suite / blockchain-tests (push) Failing after 30s
Type Check / type-check (map[directory:. name:root]) (push) Failing after 23s
Type Check / type-check (map[directory:api name:api]) (push) Failing after 21s
Type Check / type-check (map[directory:portal name:portal]) (push) Failing after 19s
Validate Configuration Files / validate (push) Failing after 1m52s
CD Pipeline / Deploy to Production (push) Has been skipped
Co-authored-by: Cursor <cursoragent@cursor.com>
2.3 KiB
2.3 KiB
250GB SSDs Status - Visible and Ready
Date: 2025-12-13
Status: ✅ ALL 6 DRIVES VISIBLE AND READY
Current Status
✅ All 6x 250GB SSDs Detected
| Drive | Size | Model | Partition | Status |
|---|---|---|---|---|
| sdc | 232.9G | CT250MX500SSD1 | sdc1 (232.9G) | ✅ Ready |
| sdd | 232.9G | CT250MX500SSD1 | sdd1 (232.9G) | ✅ Ready |
| sde | 232.9G | CT250MX500SSD1 | sde1 (232.9G) | ✅ Ready |
| sdf | 232.9G | CT250MX500SSD1 | sdf1 (232.9G) | ✅ Ready |
| sdg | 232.9G | CT250MX500SSD1 | sdg1 (232.9G) | ✅ Ready |
| sdh | 232.9G | CT250MX500SSD1 | sdh1 (232.9G) | ✅ Ready |
Key Observations
- ✅ All drives visible to the system
- ✅ Partitions created (sdc1, sdd1, etc.)
- ✅ No filesystem (FSTYPE empty) - clean and ready
- ✅ Not mounted - available for use
- ✅ Proxmox can see them - ready for storage configuration
Proxmox Storage Status
Current storage pools:
- ceph-fs: inactive (mount error - needs fixing)
- ceph-rbd: inactive
- local: active (81.5 GB)
- local-lvm: active (179.6 GB)
Next Steps
Option 1: Create Ceph OSDs (Recommended)
Use these drives for Ceph OSDs to fix the TOO_FEW_OSDS error:
# Remove partitions first (Ceph needs raw devices)
for drive in sdc sdd sde sdf sdg sdh; do
wipefs -a /dev/$drive
ceph-volume lvm create --data /dev/$drive
done
Option 2: Add as Proxmox Storage
Add them as Directory or LVM storage in Proxmox:
- Via Web UI: Datacenter > Storage > Add
- Via CLI: Use
pvesmcommands
Option 3: Use for Ceph OSD (One at a Time)
Start with one drive to fix the immediate issue:
# Use sdc for third OSD
wipefs -a /dev/sdc
ceph-volume lvm create --data /dev/sdc
# Verify
ceph osd tree
ceph health
Summary
Current State
- ✅ 6x 250GB SSDs formatted and visible
- ✅ Partitions created (ready for use)
- ✅ No filesystem (clean slate)
- ✅ Proxmox can see them
Ready For
- ✅ Ceph OSD creation
- ✅ Proxmox storage configuration
- ✅ Any storage use case
Next Action
Choose how to use the drives:
- Ceph OSDs (fixes TOO_FEW_OSDS error)
- Proxmox storage (for VMs)
- Both (some for Ceph, some for storage)
Last Updated: 2025-12-13
Status: ✅ DRIVES READY - CHOOSE USE CASE