# Complete Status Report - sfvalley-01 Cluster **Date**: 2025-12-15 14:55 PST **Cluster Name**: sfvalley-01 **Report Type**: Pre-Change Status Poll ## Proxmox Cluster Status ### ✅ **HEALTHY - Quorum Established** **Cluster Information:** - **Name**: sfvalley-01 - **Config Version**: 2 - **Transport**: knet - **Secure Auth**: Enabled **Quorum Status:** - **Status**: ✅ Quorate - **Expected Votes**: 2 - **Total Votes**: 2 - **Quorum**: 2 **Cluster Members:** - **Node 1**: ml110-01 (192.168.11.10) - Node ID: 0x00000001 - **Node 2**: r630-01 (192.168.11.11) - Node ID: 0x00000002 **Status**: ✅ Both nodes are active and in quorum --- ## Ceph Cluster Status ### ⚠️ **PARTIALLY OPERATIONAL - Monitor Issues** **Cluster Configuration:** - **FSID**: f601f0e2-cd09-402f-9e15-4b1c9a7a7b25 - **Network**: 192.168.11.0/24 (public and cluster) - **Pool Settings**: - Default size: 3 - Default min_size: 2 ### ML110-01 (192.168.11.10) Status **Services:** - ✅ **ceph-mon@ml110-01.service**: ACTIVE (running) - Status: Running but in "probing" state - Started: Mon 2025-12-15 14:39:30 PST - Memory: 142.7M - Issue: Reporting slow operations (1800+ slow ops) - ✅ **ceph-mgr@ml110-01.service**: ACTIVE (running) - Status: Running - Started: Mon 2025-12-15 14:39:33 PST - Memory: 327.3M - Issue: Authentication errors with monitor **Data Directories:** - ✅ `/var/lib/ceph/mon/ceph-ml110-01/` - Exists - ✅ `/var/lib/ceph/mgr/ceph-ml110-01/` - Exists - ⚠️ `/var/lib/ceph/osd/` - Empty (no OSDs) ### R630-01 (192.168.11.11) Status **Services:** - ❌ **ceph-mon@r630-01.service**: FAILED - Status: Failed (exit-code) - Error: Monitor data directory does not exist - needs 'mkfs' - Last attempt: Mon 2025-12-15 14:43:39 PST - Issue: Monitor filesystem not created - ✅ **ceph-mgr@r630-01.service**: ACTIVE (running) - Status: Running - Started: Mon 2025-12-15 14:39:47 PST - Memory: 326M - Issue: Reporting status from non-daemon mon.r630-01 **Data Directories:** - ⚠️ `/var/lib/ceph/mon/ceph-r630-01/` - Exists but EMPTY (needs mkfs) - ✅ `/var/lib/ceph/mgr/ceph-r630-01/` - Exists - ⚠️ `/var/lib/ceph/osd/` - Empty (no OSDs) ### Ceph Cluster Access **Status**: ⚠️ **TIMEOUT ISSUES** - `ceph -s`: Timeout - `ceph mon dump`: Timeout - `ceph osd tree`: Timeout - `pveceph status`: Timeout **Root Cause**: Monitor on ml110-01 is in "probing" state and cannot form quorum without r630-01 monitor. This causes all Ceph commands to timeout. --- ## Configuration Files ### `/etc/pve/ceph.conf` (Synced across cluster) Both nodes have identical configuration: ``` [global] auth_client_required = cephx auth_cluster_required = cephx auth_service_required = cephx cluster_network = 192.168.11.0/24 fsid = f601f0e2-cd09-402f-9e15-4b1c9a7a7b25 mon_allow_pool_delete = true mon_host = 192.168.11.10 ms_bind_ipv4 = true ms_bind_ipv6 = false osd_pool_default_min_size = 2 osd_pool_default_size = 3 public_network = 192.168.11.0/24 [client] keyring = /etc/pve/priv/$cluster.$name.keyring [client.crash] keyring = /etc/pve/ceph/$cluster.$name.keyring [mon.ml110-01] public_addr = 192.168.11.10 ``` **Note**: Configuration only lists ml110-01 in mon_host. r630-01 monitor needs to be added. --- ## Issues Identified ### Critical Issues 1. **R630-01 Monitor Not Operational** - Monitor service failed - Monitor filesystem not created - Needs: `ceph-mon --mkfs` to create filesystem - Impact: No quorum, cluster commands timeout 2. **Monitor Quorum Not Established** - Only 1 monitor running (ml110-01) - ml110-01 monitor in "probing" state - Cannot form quorum with single monitor - Impact: Cluster inaccessible 3. **Ceph Commands Timing Out** - All `ceph` commands timeout - Cannot query cluster status - Impact: Cannot manage cluster ### Warning Issues 1. **No OSDs Configured** - No OSDs on either node - Cluster has no storage - Impact: Cannot store data 2. **Monitor Configuration Incomplete** - `mon_host` only lists ml110-01 - r630-01 monitor not in configuration - Impact: r630-01 monitor cannot be discovered 3. **Slow Operations on Monitor** - ml110-01 monitor reporting 1800+ slow operations - May indicate performance issues - Impact: Degraded performance --- ## Required Actions ### Priority 1: Fix R630-01 Monitor (CRITICAL) **Steps:** 1. Get monmap and keyring from ml110-01 2. Create monitor filesystem on r630-01 3. Start monitor service 4. Verify quorum established **Commands:** ```bash # On ml110-01 ceph mon getmap -o /tmp/monmap scp /tmp/monmap root@192.168.11.11:/tmp/ scp /etc/pve/priv/ceph.mon.keyring root@192.168.11.11:/tmp/mon-keyring # On r630-01 mkdir -p /var/lib/ceph/mon/ceph-r630-01 chown ceph:ceph /var/lib/ceph/mon/ceph-r630-01 ceph-mon --mkfs -i r630-01 --monmap /tmp/monmap --keyring /tmp/mon-keyring chown -R ceph:ceph /var/lib/ceph/mon/ceph-r630-01 systemctl start ceph-mon@r630-01.service ``` ### Priority 2: Update Monitor Configuration **Steps:** 1. Add r630-01 to mon_host in ceph.conf 2. Add [mon.r630-01] section 3. Verify configuration syncs to both nodes ### Priority 3: Verify Quorum **Steps:** 1. Check monitor quorum: `ceph quorum_status` 2. Verify both monitors in quorum 3. Test cluster access: `ceph -s` ### Priority 4: Add OSDs **Steps:** 1. Identify available disks (6x 250GB SSDs on r630-01) 2. Create OSDs using `pveceph osd create` 3. Verify OSD status --- ## Summary ### ✅ Working - Proxmox cluster: Healthy, quorum established - Ceph packages: Installed on both nodes - Ceph manager: Running on both nodes - Ceph monitor: Running on ml110-01 - Configuration: Synced across cluster ### ⚠️ Needs Attention - Ceph monitor: r630-01 monitor needs filesystem creation - Monitor quorum: Cannot form quorum with single monitor - Cluster access: Commands timing out - OSDs: No OSDs configured ### ❌ Blocking Issues - R630-01 monitor not operational (blocks quorum) - Cluster commands timing out (blocks management) --- ## Next Steps 1. **Fix r630-01 monitor** (see Priority 1 above) 2. **Update monitor configuration** to include r630-01 3. **Verify quorum** and cluster access 4. **Add OSDs** once cluster is operational 5. **Monitor performance** for slow operations --- ## Notes - Proxmox cluster "sfvalley-01" is healthy and operational - Ceph cluster exists but needs monitor quorum to be fully operational - All configuration is synced via Proxmox cluster filesystem - Both nodes have Ceph installed and partially configured - Once monitor quorum is established, cluster should become fully accessible